Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Home | Products | PA/GA systems | TOP-DIS-IP2 Intercom call station

TOP-DIS-IP2 Intercom call station

TOP-DIS-IP2 intercom call station is used together with dedicated Armtel SIP server (Armtel ICS Server) or it can be used in serverless Armtel IPN intercom and public address system. Operator intercom stations can be placed on a table, built into a control desk, or mounted on a wall. Operator intercom stations can be individually equipped with a handset (TOP-HS-IP2).

Color 4.3 TFT display shows different types of information, e.g. name of subscriber, connection type (simplex or duplex), call history.

Parameter
Value
Electrical parameters
Rated voltage PoE (IEEE 802.3at), V
48
Supply voltage range PoE (IEEE 802.3at) at turn on, V
42…60
Supply voltage range PoE (IEEE 802.3at) after turn on, V
36…60
External DC power supply, V
12
External DC power supply range, V
±10%
Reverse polarity protection
available
Maximum current consumption by PoE line, max*, А
0,36
Maximum current consumption at 12 V, max*, А
1,31
Power consumption, max, W
19,1
Output voltage supply of additional modules on the I^2
C line, V
(5,0 ± 0,25)
Rated output voltage supply of peripheral devices on USB line**, V
5,0
Acoustic path
Speech bandwidth at 0.3 dB level, Hz
from 300 to 6800
Built-in speaker, pcs.
1
Gooseneck microphone, pcs.
1
Data lines
Ethernet communication interface***
10BASE-T (IEEE802.3i)
100BASE-TХ (IEEE802.3u)
Channel bonding
(IEEE802.3ad)
Communication protocols via Ethernet
SIP, «Armtel-IP»
Communication buses with auxiliary modules
I2C (Armtel),
USB 2.0
Wireless communication interface
Wi-Fi 2.4, 5.0
Communication protocols via Wi-Fi
IEEE 802.11a/b/g/n/ac
External Connection Interfaces
Ethernet connection, pcs
2 (RJ45 / 8P8C)
Auxiliary modules I2C connection, pcs
2 (RJ25 / 6P6C)
Handset connection, pcs
2 (RJ22 / 4P4C)
Auxiliary modules USB 2.0 connection, pcs.
1 (USB type A)
Additional power connection, pcs
1 (DC2,1x5,5 socket)
Controls and information display
Functional keys, pcs.
42
Display 4,3”, pcs.
1
LED indication
Microphone
Functional keys
Housing
Ethernet sockets
Operational parameters
Electrical safety class under GOST IEC 61140-2012
III
Protection degree provided by shells
IP42
Climatic category according GOST 15150-69
NF4.1 (Conditioned locations or partially conditioned air)
Ambient temperature range****, ºC
from -20 to +40
Atmospheric pressure, kPa
from 84 to 106,7
Air relative humidity at the temperature of 25 °С, %
up to 80
Design parameters
Overall dimensions*****, no more, mm
275×246,5×141
Weight, kg
(1,56 ± 5%)
* Excluding consumption currents TOP-EC-IP2 and TOP-HS-IP2.
** USB line output voltage limit accordance with USB 2.0 specification.
*** Two Ethernet ports, one of which is a reserve, including the power of PoE.
**** The limiting low ambient temperature, after the effect of which, the normal functioning of
the product is guaranteed - minus 20 °C.
***** Dimensions of the housing without the gooseneck microphone in the desktop version.

TOP-DIS-IP2 master call station is used together with dedicated Armtel SIP server (ArmtelICS central exchange) or it can be used in serverless Armtel digital Intercom and PAGA communication systems.
Depending on the application, master call station can be placed on a desktop, installed into a control desk, or mounted to a wall. If required, master call station can be individually equipped with a handset (TOP-HS-IP2).
Color 4.3 TFT display shows different types of information, e.g. name of calling subscriber, connection type (simplex or duplex), call history. TOP-DIS-IP2 is designed for installation in operator control rooms, offices and premises.

  • IP desktop intercom station for use in control rooms or control centers;
  • Color TFT display 4.3 inch;
  • 42 mechanical keys with multi-color status indications (e.g. call signaling);
  • Network connection via dual Ethernet interface (10/100 Base-TX) ;
  • Network connection via WiFi IEEE 802.11 (optional);
  • PoE or external power supply;
  • Audio bandwidth of up to 14 kHz;
  • Degree of protection IP42;
  • Simplex and duplex connections;
  • All keys are freely programmable.
Document
Version
Language
Date
Action