DCP/MDK Radio connection gateway

The gateway for connecting of base radio station provides interfacing between a base radio station and digital Armtel DCN and IPN systems. The gateway enables to connect base radio stations such as MOTOROLA GM340 and GM360 or similar to analogue interfaces of the above mentioned systems for communicating with radio network subscribers. The gateway is located near a base FM-radio station or mounted in telecom cabinets or racks, control rooms or office premises.

Parameter
Value
Rated DC power supply voltage
48 V
Supply voltage range
from 36 to 60 V
Max. operating current without radio station connected
50 mA
Max. operating current with radio station connected
750 mA
Climatic version, atmosphere type by GOST 15150-69
NF4.1
Ambient air permissible temperature range
from -5 to +55 ºC
Atmospheric pressure
from 84 to 106,7 kPa
Relative humidity at 25 ºC
up to 80 %
Electrical protection class by GOST IEC 61140-2012
III
Dimensions
125×72×66 mm
Weight
(0,16 ± 0,01) kg
Radio base station line parameters:
Rated analogue sound level at radio station input
(0,15±0,03) V
Transmission signal voltage
from +3 to +12 V
Receive signal voltage
(0 ± 2) V
Max output current
20 mA
Signals for analogue circuit control:
Rated analogue sound level
(0,78 ± 0,2) V
Voltage across AB line mid-point or control line in standby mode
Equal to supply voltage ± 5 V
Voltage across AB line mid-point or control line in active status
(0 ± 2) V

The Radio gateway for connecting of base radio station provides interfacing between a base radio station and digital Armtel DCN and IPN PAGA systems. The Radio gateway enables to connect base radio stations such as MOTOROLA GM340 and GM360 or similar to analogue interfaces of the above mentioned systems for communicating with radio network subscribers. The Radio gateway is located near a base FM-radio station or mounted in telecom cabinets or racks, control rooms or office premises.