Parameter
Value
Rated voltage*, V
48
Permissible supply voltage range*, V
from 37 to 57
Conformity with the PoE class
IEEE 802.3af Class 0
Reverse polarity protection
available
Maximum current consumption*, А
0,135
Maximum power consumption**, at least, W
5,6
Bandwidth of LF signal (–3 dB) of the transmit-receive path, Hz
from 300 to 6800
Maximum switching power of the built-in relay when connecting external actuators (within the CCS-IP3 supply voltage range)*, W
30
Maximum electric power of the built-in amplifier, at least, W
1,5
Sound pressure level of the built-in speaker at maximum volume, SPL at a distance of 1 m (0.5 m), at least, dB:
- versions from RMLT.465311.027-01 to RMLT.465311.027-05, from RMLT.465311.027-11 to RMLT.465311.027-15
- versions RMLT.465311.027, from RMLT.465311.027-06 to RMLT.465311.027-08 and RMLT.465311.027-010, from RMLT.465311.027-16 to RMLT.465311.027-18
97 (104)
92 (98)
Total duration of sound fragments stored in the device memory, at least, min
1500
Communication interfaces
IEEE 802.3u (100BaseT), IEEE 802.3i (10BaseT)
Communication protocols
SIP, Armtel-IP
Playback file format
16 kHz 16 bit mono PCM
Device status data transfer protocol
SNMP v2.0
Device configuration protocol
HTTPS
Ethernet communication interface (two Ethernet ports, one of which is redundant)
100BaseTX
Number of 100BaseTX Ethernet ports
2
Audio data format (codeс):
– via SIP protocol
– via Armtel-IP protocol
G.711A
Armtel-IP
Overall dimensions, mm:
- versions from RMLT.465311.027 to RMLT.465311.027-08
- versions from RMLT.465311.027-10 to RMLT.465311.027-18
(150 ± 1) × (265 ± 5) × (67,5 ± 1,0)
(150 ± 1) × (240 ± 1) × (67,5 ± 1,0)
Electrical characteristics of the CCS amplifier
Rated supply voltage, V
48
Permissible supply voltage range, V
от 36 до 60
Maximum current consumption, A
0,79
Output power, at least, W:
- at load resistance of 6 Ω
- at load resistance of 8 Ω
25
20
* DC supply voltage. For versions with a CCS amplifier, the amplifier is powered via a separate line.
Note – Parameter values are given without taking into account the error of measuring devices.

CCS-IP3 has a modular design and the product design varies depending on the installed modules. CCS-IP3 is produced in various office and all-weather designs, which allows the product to be used, depending on the design, in administrative premises, in open spaces and (or) at sites with increased levels of humidity, noise, dustiness and temperature, the presence of smoke, aggressive gases and chemical vapors in the air. The vandal-proof design includes built-in software and configuration data for direct communication with other subscribers of the digital communication system, processing of priority connections, control of communication modes and indication.

  • support for Armtel-IP, SIP communication protocols, the SNMP v2.0 device status data transfer protocol, and the HTTPS device configuration protocol;
  • individual simplex communication via Armtel-IP and SIP protocols;
  • indication of busy status, incoming and outgoing calls, notification of unanswered calls on target buttons using Armtel-IP and SIP protocols;
  • organisation of unilateral control of a call in simplex mode via Armtel-IP protocol;
  • manual control of duplex communication via SIP protocol;
  • support for dialer via Armtel-IP and SIP protocols;
  • individual duplex call (with the possibility of using a dialer) via SIP protocol;
  • simplex call to ACM-IP2 with activation of control lines via Armtel-IP protocol;
  • control (switching) of external actuators using a built-in relay (lamp-type signaling device);
  • the ability to organize a group simplex call using Armtel-IP and SIP protocols;
  • restoration of low-priority calls;
  • playback of fragments using Armtel-IP and SIP protocols;
  • making calls on a priority basis (up to 255 priority levels);
  • operation of the “End” function via Armtel-IP and SIP protocols;
  • adjust the volume level of the built-in speaker using the target buttons;
  • recording of speech fragments in local memory, recording of speech messages using a programmed key with a local function for recording a fragment in playback of speech messages on end devices;
  • free programming of target buttons (up to 6 pcs);
  • free addressing of subscribers for product versions with a dialer;
  • automatic playback of a message on the called subscriber’s side when pressing the direct call button of the outgoing subscriber – the “Parrot” function;
  • registration of conversations, duplication of incoming/outgoing traffic to the IP address specified in the parameters;
  • support for operation with additional external or internal 25 W amplifiers manufactured by Armtel LLC;
  • the ability to save local volume settings;
  • function of activating lines with voice call via SIP protocol (without voice call via Armtel-IP protocol);
  • a “Circular” SIP simplex group communication scenario: a special case of a conference for simplex devices with the following features – all participants of the circular can only hear the organizer of the circular, the organizer can give and take away the right to answer from a participant of the circular, when a participant answers, his answer is heard only by the organizer, each subscriber can independently leave the circular;
  • a “Selector” SIP simplex group communication scenario: a common case of a conference for simplex devices with the following features – all participants of the selector always hear only one of the participants, the organizer of the selector can give and take away the right to answer from a participant, when a participant of the selector answers, his answer is heard by all participants of the selector;
  •   PoE hot standby: redundancy is ensured by guaranteeing at least 5 mA consumption on each PoE power channel.