8 fuse module ensures short-circuit protection of power supply outputs of exchange and subscriber units of digital Armtel DCN and IPN communication systems that can occur in both communication line and inside the communication system device. Module is installed in conjunction with switching equipment of DCN, IPN communication systems in 19-inch racks or cabinets in hardware, control rooms or office premises.

Parameter
Value
Rated DC power supply voltage
48 V
Supply voltage range
from 36 to 60 V
Power line fuse capacity*
2 A
Number of power lines connected
8
Electrical protection class by GOST IEC 61140-2012
III
Atmospheric pressure
from 84 to 106,7 kPa
Climatic version, atmosphere type by GOST 15150-69
NF4.1
Seismic resistance category (under NP-031-01)
I
Safety Class (under NP-001-15** and NP-033-11)
3H
Ambient air permissible temperature range
from -5 to +55 ºC
Relative humidity at 25 ºC
up to 80 %
Clamped cable core section
from 0,2 to 2,5 sqr mm
Dimensions
125×65×66 mm
Maximum weight
0,25 kg
* It is allowed to use fuses of the power supply line with a nominal value of up to 3 A.
** The product conformity with Safety class 4H under NP-001-015 is admitted.

8 fuse module ensures short-circuit protection of power supply outputs of exchange and subscriber units of Armtel digital Intercom and PAGA communication systems, that can occur in both communication line and inside the communication system device. Module is installed in conjunction with switching equipment of communication systems in 19-inch racks or cabinets in hardware, control rooms or office premises.

  • Distribution of power supply voltage 48VDC to eight lines connected to the module through fuses;
  • Fault signal indication (any fuse blowing) byway of LED and closing relay contact. It can be used for failure signaling using external executive device (lamp, buzzer, etc.);
  • LED indication of fault at failure of any or all fuses;
  • Module is made as printed circuit board with DIN-rail 35/7.5 clamping elements. Wires of power and fault signal generation lines are connected through screw terminals.